LED lighting fittings in light alloy Zone 1 & 21 Series EVF

Flameproof LED tube light fixtures in aluminum for Zone 1 & 21 Series EVF:

The flameproof LED tube light fixtures of the EVF Series consist of a robust Aluminum housing with and impact-resistant hood in borosilicate glass. Internally, the fixtures are equipped with COSIME LTK LED tube lamps as standard. Up to 2 tube lamps can be installed per fixture, which are available in 3 lengths. Optionally, the luminaires are available with battery for emergency situations, an external LED driver for a wide voltage range or for environments with mains pollution, and with G13 lamp base for retrofit T8 LED lamps.

The lighting fixtures can be installed in Zone 1, 21, 2 & 22.

Features:

  • Ex protection: II2GD Ex the IIC T6 Gb, Ex tb IIIC T75°C Db IP66
  • Ambient temperature: -20°C ÷ +40°C/+60°C 
  • Certificate: CEC 15 ATEX 176
  • Housing: Aluminum with epoxy coating, Grey
  • Diffuser: Impact resistant UV resistant borosilicate glass
  • Screws & accessories: Stainless steel AISI 304
  • Gland entries: 1 or 2 inlets ¾"
  • LED Tubes: Cosime LTK LED Tubes (On request G13 lamp bases for T8 LED Tube Lights)
  • Luminous Flux: 900lm/W (Standard On-board Driver) or 1,150lm/W (External LED Driver)
  • Correlated color temperature (CCT): 5,500K
  • Color rendering index (CRI): > 80
  • Supply voltage: 230Vac 50/60Hz ±10% as standard
  • Battery: Ni-Cad, 3.6V 
  • LED driver: On board 230V LED driver as standard (On request, an external LED driver with wide voltage range is available)

Downloads

Product
Normal operation
Emergency operation
Classifictation
AVL10
Article: AVL10
Lighting without emergency function
5.500K
1x17W
1800 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVL210
Article: AVL210
Lighting without emergency function
5.500K
2x17W
3600 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVL230
Article: AVL230
Lighting without emergency function
5.500K
2x35W
7200 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVL30
Article: AVL30
Lighting without emergency function
5.500K
1x35W
3600 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVL310
Article: AVL310
Lighting without emergency function
5.500K
3x17W
5400 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVL330
Article: AVL330
Lighting without emergency function
5.500K
3x35W
10800 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVLE10(1H)
Article: AVLE10(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
1x17W
1800 lm
13W (1hr)
1300 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVLE10(3H)
Article: AVLE10(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
1x17W
1800 lm
4W (3Hrs)
550 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVLE210(1H)
Article: AVLE210(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
2x17W
3600 lm
13W (1hr)
1300 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVLE210(3H)
Article: AVLE210(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
2x17W
3600 lm
4W (3Hrs)
550 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVLE230(1H)
Article: AVLE230(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
2x35W
7200 lm
13W (1hr)
1300 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVLE230(3H)
Article: AVLE230(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
2x35W
7200 lm
4W (3Hrs)
550 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVLE30(1H)
Article: AVLE30(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
1x35W
3600 lm
13W (1hr)
1300 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVLE30(3H)
Article: AVLE30(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
1x35W
3600 lm
4W (3Hrs)
550 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVLEE10(1H)
Article: AVLEE10(1H)
Non-maintained emergency lighting (Operation only in case of emergency)
5.500K

lm
13W (1hr)
1300 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVLEE10(3H)
Article: AVLEE10(3H)
Non-maintained emergency lighting (Operation only in case of emergency)
5.500K

lm
4W (3Hrs)
550 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T5 Gb
II2D Ex tb IIIC T70°C IP66 Db
AVNL18
Article: AVNL18
Lighting without emergency function
2.800K ÷ 6.500K
Max 1x16W
1250 lm

-
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc
AVNL218
Article: AVNL218
Lighting without emergency function
2.800K ÷ 6.500K
Max 2x16W
2500 lm

-
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc
AVNL236
Article: AVNL236
Lighting without emergency function
2.800K ÷ 6.500K
Max 2x32W
5000 lm

-
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc
AVNL318
Article: AVNL318
Lighting without emergency function
2.800K ÷ 6.500K
Max 3x16W
3750 lm

-
Atex Zone 2 & 22
II3G Ex nA IIC T6 Gc
II3D Ex tc IIIC T80°C IP66 Dc

Emergency function

Series

More series... Less series

Atex Zone

Voltage

Ambient temperature

-

Power

-

Flux

-

CCT

-
Reset filter