LED lighting fittings in GRP Zone 1 & 21 Series AVL

LED Tube light fixtures in GRP for Zone 1 & 21 Series AVL:

AVL Series LED tube light fixtures consist of a robust GRP housing with 2.5mm thick and impact resistant UV resistant polycarbonate cover. Internally, the fixtures are equipped with Ex mb cast LTT LED tube lamps. Up to 3 tube lamps can be installed per fixture, available in two lengths. The tube lamps can be individually rotated to spread or adjust the luminous flux. Optionally, the fixtures are available with battery for emergency situations and an external LED driver for a wide voltage range or for environments with mains contamination.

The lighting fixtures can be installed in Zone 1, 21, 2 & 22.

Features:

  • Ex protection: II2GD Ex d e mb IIC T5 Gb, Ex tb IIIC T70°C Db IP66
  • Ambient temperature: -25°C ÷ +50°C 
  • Certificate: CEC 13 ATEX 024
  • Housing: Glass fiber reinforced polyester, Black
  • Diffuser: Impact resistant UV resistant polycarbonate 
  • Screws & accessories: Stainless steel AISI 304
  • Connection terminals: Terminal block 3x2.5mm²
  • Gland entries: 1 or 2 M25 entries
  • LED Tubes: Cosime LTT Ex mb (CEC 14 ATEX 054 U)
  • Luminous flux: 900lm/W (Standard On-board driver) or 1,150lm/W (External LED Driver)
  • Correlated color temperature (CCT): 5,500K
  • Color rendering index (CRI): > 80
  • Supply voltage: 230Vac 50/60Hz ±10% as standard
  • Battery: Ni-Cad, 3.6V 
  • LED driver: On board 230V LED driver as standard (On request, an external LED driver with wide voltage range is available)

Downloads

Product
Normal operation
Emergency operation
Classifictation
BTLE230RUN240(1H)
Article: BTLE230RUN240(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
2x35W
7200 lm
13W (1hr)
1300 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLE230RUN240(3H)
Article: BTLE230RUN240(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
2x35W
7200 lm
4W (3Hrs)
550 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLE30RUN240(1H)
Article: BTLE30RUN240(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
1x35W
3600 lm
13W (1hr)
1300 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLE30RUN240(3H)
Article: BTLE30RUN240(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
1x35W
3600 lm
4W (3Hrs)
550 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLEE15RUN240(1H)
Article: BTLEE15RUN240(1H)
Non-maintained emergency lighting (Operation only in case of emergency)
5.500K

lm
13W (1hr)
1300 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLEE15RUN240(3H)
Article: BTLEE15RUN240(3H)
Non-maintained emergency lighting (Operation only in case of emergency)
5.500K

lm
4W (3Hrs)
550 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
LTC05Q-230AC
Article: LTC05Q-230AC
Lighting without emergency function
5.500K
5W
450 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC05Q-24DC
Article: LTC05Q-24DC
Lighting without emergency function
5.500K
5W
500 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC05YQ-24DC
Article: LTC05YQ-24DC
Lighting without emergency function
5.500K
5W
500 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC10A-24DC
Article: LTC10A-24DC
Lighting without emergency function
5.500K
9W
1000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC10Q-230AC
Article: LTC10Q-230AC
Lighting without emergency function
5.500K
9W
900 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC10Q-24DC
Article: LTC10Q-24DC
Lighting without emergency function
5.500K
9W
1000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC10YQ-24DC
Article: LTC10YQ-24DC
Lighting without emergency function
5.500K
9W
1000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC15A-24DC
Article: LTC15A-24DC
Lighting without emergency function
5.500K
15W
1750 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC15Q-24DC
Article: LTC15Q-24DC
Lighting without emergency function
5.500K
15W
1750 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC15YQ-24DC
Article: LTC15YQ-24DC
Lighting without emergency function
5.500K
15W
1750 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC20Q-230AC
Article: LTC20Q-230AC
Lighting without emergency function
5.500K
17W
1800 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC20Q-24DC
Article: LTC20Q-24DC
Lighting without emergency function
5.500K
17W
2000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC20YQ-24DC
Article: LTC20YQ-24DC
Lighting without emergency function
5.500K
17W
2000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC30Q-230AC
Article: LTC30Q-230AC
Lighting without emergency function
5.500K
26W
2700 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db

Emergency function

Series

More series... Less series

Atex Zone

Voltage

Ambient temperature

-

Power

-

Flux

-

CCT

-