LED lighting fittings in light alloy Zone 1 & 21 Series BTL

Flameproof LED tube light fixtures in Aluminum for Zone 1 & 21 Series BTL:

BTL Flameproof LED tube light fixtures consist of a rugged Aluminum housing with and impact-resistant cap in borosilicate glass. Internally, the luminaires are standardly equipped with COSIME LTK LED tube lamps. Up to 2 tube lamps can be installed per fixture, which are available in 3 lengths. Optionally, the luminaires are available with battery for emergency situations, an external LED driver for a wide voltage range or for environments with mains pollution, and with G13 lamp base for retrofit T8 LED lamps.

The lighting fixtures can be installed in Zone 1, 21, 2 & 22.

Features:

  • Ex protection: II2GD Ex the IIC T6 Gb, Ex tb IIIC T75°C Db IP66
  • Ambient temperature: -20°C ÷ +40°C/+60°C 
  • Certificate: CEC 15 ATEX 176
  • Housing: Aluminum with epoxy coating, Grey
  • Diffuser: Impact resistant UV resistant borosilicate glass
  • Screws & accessories: Stainless steel AISI 304
  • Gland entries: 1 or 2 inlets ¾"
  • LED Tubes: Cosime LTK LED Tubes (On request G13 lamp bases for T8 LED Tube Lights)
  • Luminous Flux: 900lm/W (Standard On-board Driver) or 1,150lm/W (External LED Driver)
  • Correlated color temperature (CCT): 5,500K
  • Color rendering index (CRI): > 80
  • Supply voltage: 230Vac 50/60Hz ±10% as standard
  • Battery: Ni-Cad, 3.6V 
  • LED driver: On board 230V LED driver as standard (On request, an external LED driver with wide voltage range is available)

Downloads

Product
Normal operation
Emergency operation
Classifictation
BTLE230RUN240(1H)
Article: BTLE230RUN240(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
2x35W
7200 lm
13W (1hr)
1300 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLE230RUN240(3H)
Article: BTLE230RUN240(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
2x35W
7200 lm
4W (3Hrs)
550 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLE30RUN240(1H)
Article: BTLE30RUN240(1H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
1x35W
3600 lm
13W (1hr)
1300 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLE30RUN240(3H)
Article: BTLE30RUN240(3H)
Maintained emergency lighting (Operation under normal conditions and in case of emergency)
5.500K
1x35W
3600 lm
4W (3Hrs)
550 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLEE15RUN240(1H)
Article: BTLEE15RUN240(1H)
Non-maintained emergency lighting (Operation only in case of emergency)
5.500K

lm
13W (1hr)
1300 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
BTLEE15RUN240(3H)
Article: BTLEE15RUN240(3H)
Non-maintained emergency lighting (Operation only in case of emergency)
5.500K

lm
4W (3Hrs)
550 lm
Atex Zone 1, 2, 21 & 22
II2G Ex d e mb IIC T6 Gb
II2D Ex tb IIIC T75°C IP66 Db
LTC05Q-230AC
Article: LTC05Q-230AC
Lighting without emergency function
5.500K
5W
450 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC05Q-24DC
Article: LTC05Q-24DC
Lighting without emergency function
5.500K
5W
500 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC05YQ-24DC
Article: LTC05YQ-24DC
Lighting without emergency function
5.500K
5W
500 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC10A-24DC
Article: LTC10A-24DC
Lighting without emergency function
5.500K
9W
1000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC10Q-230AC
Article: LTC10Q-230AC
Lighting without emergency function
5.500K
9W
900 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC10Q-24DC
Article: LTC10Q-24DC
Lighting without emergency function
5.500K
9W
1000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC10YQ-24DC
Article: LTC10YQ-24DC
Lighting without emergency function
5.500K
9W
1000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC15A-24DC
Article: LTC15A-24DC
Lighting without emergency function
5.500K
15W
1750 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC15Q-24DC
Article: LTC15Q-24DC
Lighting without emergency function
5.500K
15W
1750 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC15YQ-24DC
Article: LTC15YQ-24DC
Lighting without emergency function
5.500K
15W
1750 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC20Q-230AC
Article: LTC20Q-230AC
Lighting without emergency function
5.500K
17W
1800 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC20Q-24DC
Article: LTC20Q-24DC
Lighting without emergency function
5.500K
17W
2000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC20YQ-24DC
Article: LTC20YQ-24DC
Lighting without emergency function
5.500K
17W
2000 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db
LTC30Q-230AC
Article: LTC30Q-230AC
Lighting without emergency function
5.500K
26W
2700 lm

-
Atex Zone 1, 2, 21 & 22
II2G Ex e mb IIC T5 Gb
II2D Ex mb IIIC T95°C IP66 Db

Emergency function

Series

More series... Less series

Atex Zone

Voltage

Ambient temperature

-

Power

-

Flux

-

CCT

-
Reset filter